Firmware Electronics (Suzhou) Co., Ltd.
QShortcut>QShortcut>PEL-2000
@ action
Agaji na Firam
  • @ action
    member
  • QShortcut
  • Phonon:: MMF:: EffectFactory
  • QShortcut
    No.521 Zhujiang Road, New District, Suzhou, lardin Jiangsu, ko No.69 Lushan Road
Haka
PEL-2000
10 sets of pre-saita memory iya aiki a layi daya goyon bayan load kwaikwayon jerin ayyuka waje waveform iko ayyuka . .....
@ action

PEL-2000 Shirye-shiryen DC lantarki kaya, wannan lantarki kaya iya aiki a daidaitaccen halin yanzu, daidaitaccen ƙarfin lantarki, daidaitaccen juriya yanayin, kuma zai iya kwaikwayon daban-daban m kaya yanayi, ta hanyar jerin ayyuka don kaya ƙarfin lantarki, halin yanzu, kaya ta tashi da sauka inclination, halin yanzu positioning, tsawon lokaci da sauran sigogi don gyara kaya waveform, yayin da samar da waje waveform siginar iko da kuma V&I Kulawa da aiki, gwajin sigogi da kuma jihar ajiya iya zuwa 120 sets, tsarin za a iya a kowane lokaci ta hanyar kayan aiki na ciki ajiya na'ura bisa ga atomatik gwaji bukatun EEPROM Yi amfani da kira daga.

PEL-2000 Jerin ya ƙunshi nau'ikan biyu na manyan tsarin sarrafawa PEL-2002( iya ɗaukar biyu modules) da PEL-2004( Za a iya ɗaukar hudu kayayyaki), tare da modular zane, taimaka wa masu amfani da kiyaye m iya amfani da shi a nan gaba zuwa mafi girma wutar lantarki bukatun, a halin yanzu akwai 4 nau'ikan kayayyaki ne: PEL-2020(200W Dual tashar kaya module 100 W*2 ; PEL-2030 (280W Biyu tashar kaya module 30 W+ 250W) ; PEL-2040(350W guda tashar load module); PEL-2041(350W Single tashar load module)] zuwa PEL-2004 Don wakiltar har zuwa 8 tashoshi aiki tare, ikon kewayon 200 W~350W, Yanzu kewayon 0 ~ 70 A, ƙarfin lantarki kewayon 1 ~ 500 V, Mai amfani zai iya dangane da ainihin bukatun, zaɓar nauyin kayan aiki da kuma sarrafa kayan aiki don haɗuwa ko tsarin nauyin kai, zai iya aiwatar da aikace-aikacen nauyin kayan aiki na lantarki da yawa, yayin da kowane kayan aiki ke amfani da hanyar keɓewa da ƙasa don kauce wa haifar da gajeren zagaye; Yanzu masana'antar makamashi mai kore tana bunkasa, PEL-2000 Jerin ya dace da bukatun gwajin kayan aikin lantarki masu amfani da kayan aiki masu amfani da kayan aiki masu amfani da kayan aiki masu amfani da kayan aiki masu amfani da kayan aiki masu amfani da kayan aiki masu amfani da kayan aiki masu amfani da kayan aiki masu amfani da kayan aiki masu amfani da kay kVA。

PEL-2000 jerin kayan aiki RS232、USB、GPIB( zaɓi) dubawa, GO/NG interface yayin da kuma sanye da direbobi da kuma nufin LabView、VB、C、C++ Misalai na software na gwaji da sauransu. PEL-2000 Series yafi amfani da Multi tashar ko guda tashar fitarwa AC/DC wutar lantarki, DC/DC Gwajin ikon module, caji da ikon lantarki kayan aiki, samar da sauri da inganci gwaji tsari a kan zane R & D, samar da layin gwaji da samfurin gwaji ayyuka, yayin da OPP、OCP、OVP、OTP、 Karewar ƙananan ƙarfin lantarki da ayyukan kare polar mai kyau da na baya sun haɓaka amincin samfurin, samfurin gwajin injiniya da yanayin gwajin atomatik.

lantarki Load PEL-2000 Babban aiki gabatarwa 2 (Vsense; kariya)http://v.youku.com/v_show/id_XMTQwMjUyNTMzNg==.html?spm=a2hzp.8253869.0.0

lantarki Load PEL-2000 Gabatarwa na Basic Features 6 (GO-NOGO amfani)http://v.youku.com/v_show/id_XMTQwMjUyMzc1Mg==.html?spm=a2h0j..listitem_page1.5 !24~A

lantarki Load PEL-2000 Gabatarwa na Basic Ayyuka 5 (Aikace-aikacen layi daya)http://v.youku.com/v_show/id_XMTQwMjUyMTgzNg==.html?spm=a2h0j..listitem_page1.5 !25~A

lantarki Load PEL-2000 Basic Feature Gabatarwa 4 (Sequence amfani)http://v.youku.com/v_show/id_XMTQwMjUxOTcwNA==.html?spm=a2hzp.8253869.0.0

lantarki Load PEL-2000 Gabatarwa na Basic Features 3 (Aikace-aikacen da aka riga aka saita)http://v.youku.com/v_show/id_XMTQwMjUxODgwOA==.html?spm=a2hzp.8253869.0.0

lantarki Load PEL-2000 Basic aiki gabatarwa 1 (yanayin, tashar canzawahttp://v.youku.com/v_show/id_XMTQwMjUxNjYyOA==.html?spm=a2hzp.8253869.0.0

A. AUTOMATICALLY SEQUENCE FUNCTION

The Sequence function allows each channel to change its load sink according to a predefined sequence at a rate of up to 100 s per step. Each sequence is able to run concurrently, under the control of one clock. This is one of the most powerful features of the PEL-2000 Series as it is able to realistically simulate a multi-output power supply load. Under Dynamic mode, the load current or load resistance pulses between two preset levels at a pre-defined speed up to 25 s per step. This is often used as the standard test procedure to verify the response of a power supply to quick load changes.

The picture above is an example of a sequence used as a load profile for a single output switching power supply. A load profile is programmed to simulate the current draw of a power supply load. By using a current probe to acquire a current waveform, the PEL-2000 is able to evaluate the performance of a power supply based on the load sequence that is programmed. An oscilloscope is then used to display the result.


B. MULTIPLE OPERATING MODE

C.C. ( Constant Current )

In Constant Current mode, a load unit will sink the amount of current programmed. Regardless of the voltage change, the current will stay the same. Two selectable ranges are available for constant current mode: High (HI) and low (LO) range. Low range has a higher resolution for high precision measurements. If the current exceeds the low range, high range must be used. The PEL-2000 Series offers the maximum rated power for the low measurement range. This unique feature enables high-resolution measurements at high voltage only if the load current doesn't exceed the rated low range level. Both static and dynamic modes are available for CC operation. Static mode can be used for stability tests and Dynamic mode can be used to test transient load performance of a power supply. Go/NoGo is supported for both high and low ranges as well as Static and Dynamic modes.


C.V. ( Constant Voltage )

In Constant Voltage mode the load unit will sink current whilst keeping the voltage constant. Under CV mode, single channel load modules support two levels of voltage (A Value, B Value) with a preset cut-off current limit. An A / B button is available on the load module front panels to switch the Constant Voltage between A Value and B Value for power supply load regulation testing. Dual channel load modules only support A Value for CV mode. To accommodate the response of a power supply, response rates during voltage transitions can be set to fast or slow under static test mode.


C.V.+C.C. ( Constant Voltage + Constant Current )

When using CV mode, a current limit can be set for CV+CC mode. If the input voltage is greater than the preset CV limit, the channel will operate in CV mode if the input current is less than the preset CC limit. When the input current exceeds the current limit, the channel will operate in CC mode.


C.R. ( Constant Resistance )

In Constant Resistance mode the load units will linearly sink current and voltage to match a set resistance. Two different CR values and two different rising and falling slew rates can be set under CR Mode for single channel load modules. Like CC mode, Constant Resistance mode supports both dynamic and static loads. As with the other modes, Go/No Go is also supported.


C. PARALLEL DYNAMIC LOADING

All the load channels in a PEL-2000 mainframe can be connected in parallel to perform any combination of static or dynamic loading. Under Dynamic mode, the load current or load resistance pulses between two preset levels at a predefined speed of up to 25 s per step. When the channels are connected in parallel, dynamic tests are synchronously clocked. The ability to perform parallel dynamic loading gives you the flexibility to perform dynamic tests to highpower power supplies without the need for a dedicated high power electronic load.


D. FRAME LINK

The PEL-2000 Series allows multiple mainframes to be linked together with standard MIL 20-pin connectors to provide higher power load capacity. A maximum of 5 mainframes maximum, including one master and 4 slaves, can be chained together to give a 7kW load capacity for high current and high power applications


E. RUN PROGRAM

Under 'Program' mode, up to 12 programs each with 10 panel setup memories, can be edited to create work routines for repetitive tests. After a program has completed, the results of all test steps, including the Go/NoGo judgments will be shown on the screen. Up to 12 programs with a total of up to 120 panel-setup memories can be chained together to be run one after the other.


F. PROTECTION MODES

The PEL-2000 Series includes a number of protection modes: Over Current Protection (OCP), Over Voltage Protection (OVP), Over Power Protection (OPP), Reverse Voltage Protection (RVP), and Under Voltage Protection (UVP). The protection modes are useful to protect both the load modules and the DUT(s). A buzzer can be set for when a protection setting has been tripped. When a protection mode has been tripped, the load unit will display an alarm and stop sinking current/voltage. When a load unit is operating in CR or CV mode, the unit may need Over Current Protection to prevent excessive current being sunk. Over Current Protection stops the load from sinking more current than its recommended limit and prevents the load from burn-out damage. Over Voltage Protection is used to limit the amount of voltage sunk. If the OVP trips, the PEL-Series load will stop sinking voltage. Over Power Protection is used when the input power exceeds the specifications of the load. When OPP is tripped, the power will cease to be sunk. Reverse Voltage Protection prevents reverse voltage damage to the PEL-2000 Series up to the specified rating. When Reverse Voltage Protection has been tripped, an alarm tone will sound until the reverse voltage is removed. Under Voltage Protection will turn off the load when the voltage drops below a set limit.


G. Von VOLTAGE SETTINGS

Von Voltage is the voltage limit at which the load will start to sink current. The Von Voltage setting is necessary for some kinds of power supply if a heavy load is connected during load on. There are two operation modes for Von Voltage: Latch ON and Latch OFF. When Von Latch is set to ON, the load starts to sink current when input voltage exceeds Von, and will continue to sink current even if the voltage drops below the Von Voltage later. When Von Latch is set to OFF, the load starts to sink current when input voltage exceeds Von, but will stop sinking current when the voltage drops below the Von voltage setting. This is to prevent the power supply from running into oscillation when the output voltage goes below certain level.


H. EXTERNAL CHANNEL CONTROL

A six-pin analog control connector is available on the rear panel to externally turn a load on/off and to externally monitor the load input status of each channel, including input current, input voltage, and CC current or CV settings. The Voltage Monitor Output (VMON) and Current Monitor Output (IMON) output the load input voltage and load input current as a percentage of rating current/voltage. Where 0 volts = 0% rating and 10 volts = 100% load input rating voltage or current. The voltage monitor output is across pins 1 & 3, and the current monitor output is across pins 1 & 2. Below shows the pin configuration of the voltage and current monitor outputs.

To turn a load on, an active low voltage (0-1V) must be applied across Load On (pin 5) and GND (pin 1), similarly an active high voltage (4-5V) must be applied to turn a load off. The Load On input must be TTL.

QNetworkAccessFileBackend
  • QShortcut
  • QShortcut
  • QShortcut
  • Email
  • Dakata
  • @ action
  • @ action

Socket error code ConnectionTimedOut

Socket error code ConnectionTimedOut

Socket error code ConnectionTimedOut